Properly understood and applied, conductivity is probably simpler to operate and maintain than any other analytical measurement. Each type of sensor has certain applications for which it is best suited. Most applications decisions involve the sensor more than the instrument. Modern instruments are so featured-packed that they will cover almost any application, but not so the sensors. They are where the measurement system meets the process.

CS52 Conductivity Sensors

  • Very compact size for a high cell constant of K=10.0
  • O-ring seals used on all versions for high on-stream reliability
  • Thermowell for the temperature element gives rapid response

This sensor has a small footprint for its high probe constant of K=10.0. Its size and economical pricing make it ideal for use in various OEM applications, such as skid mounted R.O. systems, water treatment units, chemical dilutions, and many more.

Application Notes

Wetted materials of construction are 316 stainless steel and CPVC, with double EPR o-ring seals. The outer o-ring is the only one to touch the process fluid, allowing the rear seal to operate free from chemical attack. The thermowell containing the temperature sensing element in its tip is exposed directly to the stream, assuring rapid automatic compensation for maximum accuracy. Process connections are 3/4″ NPT for insertion, and the back portion is 3/4″ stainless steel tubing, which can be gripped by a swage fitting for submersion applications. When longer cable runs than the standard ten feet are required, a junction box can be attached to the back of the sensor in the same manner. A Teflon insulator is available as an option to the standard CPVC.

cn_img4

TEMPERATURE COMPENSATION:

Available options include Pt1000, Pt100, 3K
BALCO, 8,55K NTC, Ni100 and many others.
Reference the make and model of instrument
for assistance in selecting the right element.

SPECIFICATIONS

MAX. PRESSURE/TEMP. RATINGS:

100 PSIG at 95ºC
500 PSIG at 50ºC

WETTED MATERIALS:

Electrodes – 316 Stainless Steel
Insulator – CPVC
O-Rings – EPDM FDA APPROVED

CONNECTIONS:

Process – 3/4” NPT
Electrical – Stripped and tinned 24 gauge

CELL CONSTANT:

10.0